Adhesivos Soltec SL has been granted ETA 24/0066 for its SOLTEC PANEL-FIX kit used for the adhesion of façade panels.
The SOLTEC PANEL-FIX kit consists of SOLTEC PANEL-FIX polymer adhesive and SOLTEC PANEL-FIX 451SW primer, and is used for the adhesion of opaque façade cladding panels on the aluminium profiles of the substructure.
ABOUT EXPERIMENT PARTNER AND PRODUCT
The tested solution is an innovative multifunctional façade system integrating IoT, heat pumps, automatic blinds and windows to ensure indoor comfort and energy efficiency.
01 September, 2024
The company FlexoFibers Europa SL has obtained the ETA 23/0933 for its steel fibers FLEXOFIBER® FX from the recycling of used tyres, for reinforcing mortars and concrete.
FLEXOFIBER® FX-20 and FLEXOFIBER® FX-25 steel fibers are obtained from recycled tyres (cold drawn filaments with high tensile strength). FLEXOFIBERS selects the fibers, eliminates excess rubber and classifies the fibers by size (length and diameter), to generate two commercial products for reinforcing mortars and concrete:
PM&VL 6
Multifunctional, multilayer façade systems
PM&VL6 offers a comprehensive characterization of building envelope components, thanks to its two infrastructures: the Materials & Structures Laboratory (M&S Lab, mechanical characterization) and the BEEpilot (thermal, hygrothermal, air quality and airtightness performances).
Overview
Health
Hygiene, health, environment
30 July, 2023
Thermal conductivity of a material is a basic feature of thermal insulation. The test is conducted using the FOX 314 Lasercomp Inc. device, with a measurement range of 0.01 - 0.2 W/mK. Depending on the type of material, the tests are conducted in accordance with:
EN 12664: 2001 Thermal properties of building materials and products - Determination of thermal resistance using the shielded hotplate and heat flow meter methods - Dry and moist products with medium and low thermal resistance.
Thermal conductivity of a material is a basic feature of thermal insulation. The test is conducted using the FOX 314 Lasercomp Inc. device, with a measurement range of 0.01 - 0.2 W/mK. Depending on the type of material, the tests are conducted in accordance with:
EN 12664: 2001 Thermal properties of building materials and products - Determination of thermal resistance using the shielded hotplate and heat flow meter methods - Dry and moist products with medium and low thermal resistance.
The determination of the internal surface temperature in terms of critical surface humidity is determined using calculation (simulation) software in accordance with the standard:
EN ISO 13788:2012 Hygrothermal performance of building components and building elements. Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methods.
The determination of the internal surface temperature in terms of critical surface humidity is determined using calculation (simulation) software in accordance with the standard:
EN ISO 13788:2012 Hygrothermal performance of building components and building elements. Internal surface temperature to avoid critical surface humidity and interstitial condensation. Calculation methods.
The determination of the internal surface temperature in terms of critical surface humidity is determined using calculation (simulation) software in accordance with the standard